The S2352P-EI version

I am now machine is LS-S2326TP-EI-AC,
Version: S2352_S3352-V100R003C00SPC301.cc; patch file: s23_33_53-v100r003sph005.pat
Files in Flash are as follows:
Directory of flash:/
0 -rw- 7236892 Jan 012008 00:08:01 S2352_S3352-V100R003C00SPC301.cc
1 -rw- 344778 Jan 012008 00:11:50 s23_33_53-v100r003sph005.pat
2 -rw- 60 Jan 012008 00:33:56 $_patchstate_a
3 -rw- 37 Jan 012008 00:37:19 private-data.txt
4 -rw- 4 Jan 012008 00:17:03 notilogindex.txt
5 -rw- 6808 Jan 012008 00:37:02 patchhistory
6 -rw- 784 Jan 012008 00:35:10 vrpcfg.zip
14632 KB Total (7184 KB free)
I see the most recent version website is:
S2300EI-V100R006C05.zip you do not have permission to view
17.15MB 2013-11-22
S2300_V100R006SPH015.pat you do not have permission to view
817.57KB 2013-10-16

Then ask,
First S2300EI-V100R006C05.zip in what documents are included, if only. Cc, that my machine 16M of memory, can hold ah? Or included. Cc other files?
Again, I can upgrade to this latest version? And apply the latest patch files: S2300_V100R006SPH015.pat it?
In addition, the version of the new, enhanced, machine stability will be affected?
Now enough authority, can not be downloaded, first ask the

There are two packages unpacked, there bootrom, web package, S2326TP-EI -V100R006C05.cc This document is only a little more than 8M.

I can elevate privileges to the inside space, follow the prompts, association like about the product serial number, cassette product knock display elable, barcode that saw a string of characters, lost in, a working day, someone to help you enhance privileges .

2014年1月9日星期四

Configuring the VoIP Service (H.248-based and SIP-based)

The MA5620  /MA5626   /MA5608T supports the H.248-based VoIP service and the SIP-based VoIP service at the same time.

Configure the working mode of the ISDN BRA port.
In the BRA port mode, configure the working mode of the ISDN BRA port to P2P, configure the activation mode to stable activation, and disable automatic activation.

huawei(config)#braport
huawei(config-braport)#braport attribute set 0/2/0 workmode p2p activemode stable-active autodeactive disable
huawei(config-braport)#quit
Add an IUA link set and IUA links.
In the SIGTRAN mode, configure the SIGTRAN protocol stack. Add an IUA link set, and then add IUA links.

huawei(config)#sigtran
huawei(config-sigtran)#iua-linkset add 1 mgid 0 jointly-work enable trafficmode override
iid-map 2 pendingtime 1 cs-mode client
huawei(config-sigtran)#iua-link add 15 1 1401 10.13.4.116 1400 10.14.1.2
jointly-work-with primary-mgc priority 3
huawei(config-sigtran)#quit
 NOTE:
All the ISDN call control messages are sent from the IUA link to the softswitch, whereas the system uses the bearer control messages to communicate with the softswitch through H.248.
Configure the ISDN BRA user data.
huawei(config)#esl user
huawei(config-esl-user)#mgbrauser add 0/2/0 0 1 interfaceid 8 terminalid 100 telno 12345601

huawei(config-esl-user)#quit

Configuring the GE/FE Optical/Electrical Interface

Generally, the ME60-X3  /NE40E-X8    sets an Ethernet interface to an optical or electrical interface based on the interface module's type. If the NE80E/40E cannot identify an interface module, you need to manually set the interface to the optical or electrical mode.

Run:
system-view
The system view is displayed.
Run:
interface { ethernet | gigabitethernet } interface-number
The Ethernet interface view is displayed.
Run:
port-type { copper | fiber-100 | fiber-1000 }
The interface type is set.

NOTE:
When an SFP module is being replaced, the configurations such as the loopback test, interface speed, auto-negotiation mode, and duplex mode on the interface are all restored to default ones. You need to reconfigure them on the interface.
After the port-type command is run, the configurations such as the loopback test, interface speed, auto-negotiation mode, and duplex mode on the interface are all restored to default ones. You need to reconfigure them on the interface.

The parameter copper can be configured in the port-type command only when an optical/electrical SFP module is installed.

2014年1月7日星期二

Configure the interface mode to user termination. # Configure PE1.

[PE1] interface LS-S2318TP-EI-DC   gigabitethernet 1/0/0
[PE1-GigabitEthernet1/0/0] mode user-termination
[PE1-GigabitEthernet1/0/0] undo shutdown
[PE1-GigabitEthernet1/0/0] quit
# Configure PE2.

[PE2] interface gigabitethernet 2/0/0
[PE2-GigabitEthernet2/0/0] mode user-termination
[PE2-GigabitEthernet2/0/0] undo shutdown
[PE2-GigabitEthernet2/0/0] quit
Configure the sub-interface for dot1q VLAN tag termination and bind VSIs and AC interfaces.
# Configure PE1.

[PE1] interface gigabitethernet 1/0/0.1
[PE1-GigabitEthernet1/0/0.1] control-vid 1 dot1q-termination
[PE1-GigabitEthernet1/0/0.1] dot1q termination vid 10
[PE1-GigabitEthernet1/0/0.1] l2 binding vsi ldp1
[PE1-GigabitEthernet1/0/0.1] undo shutdown
[PE1-GigabitEthernet1/0/0.1] quit
# Configure PE2.

[PE2] interface gigabitethernet 2/0/0.1
[PE2-GigabitEthernet2/0/0.1] control-vid 1 dot1q-termination
[PE2-GigabitEthernet2/0/0.1] dot1q termination vid 10
[PE2-GigabitEthernet2/0/0.1] l2 binding vsi ldp1
[PE2-GigabitEthernet2/0/0.1] undo shutdown
[PE2-GigabitEthernet2/0/0.1] quit
 NOTE:
On different sub-interfaces LS-S2326TP-EI-AC , the vid values cannot overlap.


2014年1月6日星期一

configuration notes for the ME60

03030BXN     Switch Fabric Unit         SFUA0s are no longer manufactured and are unavailable for the ME60-16 running V600R002. When an SFUA0 that has already been installed on an ME60-X3 fails, an SFUA1 can be used to replace the faulty SFUA0; if the SFUA0 is to be replaced with an SFUG1, software of the ME60-16 needs to be upgraded to V600R002 or later.

03030GFW    Switch Fabric Unit         ME01SFUA1 (SFUA1) (03030GFW) is not a preferred board in V600R002. The SFUA1 is developed based on the ME01SFUA0 in V100R005; therefore, the SFUA1 is compatible to the SFUA0. In addition, the system synchronous clock module is added to the SFUA1. The SFUA1 exchanges data at the line rate between 16 OC-192c user interfaces. The switching capacity is 640 Gbit/s and the user interface capacity is 320 Gbit/s.
An SFUA1 can be inserted to the BSUF-10 or MSUF-10, not the BSUF-21, BSUF-40, MSUF-21, or MSUF-40. Three or four SFUA1s are provided for an ME60-16. Installing four SFUFs on an ME60-16 is recommended. If there is one SFUA1, it is installed in either slot 21 or 22, two SFUA1s use slots 21 and 22, and if a third board is installed, it is in either slot 19 or 20.

It is preferred. The SFUG1 is developed for V600R002 and applies to an ME60-16. The SFUG1 is installed in the SFU slot of the chassis. The SFUG1 uses new switching chipsets, and exchanges data at the line rate between 16 OC-768c user interfaces. The switching capacity is 2.56 Tbit/s and the available user interface capacity is 1.28 Tbit/s.


The boards with fixed interfaces, such as BSU/MSU, BSUF-10, MSUF-10, BSUF-21, MSUF-21, BSUF-40, and MSUF-40 support SFUG1s. The SFUG1 of V600R002 allows the interconnection between a 10 Gbit/s LPU and a 20 Gbit/s LPU. Three or four SFUG1s are provided for an ME60-16. Installing four SFUG1s on an ME60-16 is recommended. If there is one SFUG1, it must be installed in either slot 21 or 22, two boards must use slots 21 and 22, and if a third board is installed, it must be in either slot 19 or 20. The SFUG1 is mandatory for the ME60-16 installed with the BSUF-21 or MSUF-21, and the ME60-16 that will be installed with the BSUF-21, MSUF-21, BSUF-40, or MSUF-40 after upgrade.

2014年1月2日星期四

Configuring a Working Mode for an APS Group

A working mode can be configured for an APS group. The ME60-X3  /NE40E-X3    supports APS working modes, including automatic APS switching, and delayed switchback with the wait to restore (WTR) time configured. An APS working mode must be configured on a protect interface.
Run:
system-view
The system view is displayed.
Run:
interface interface-type interface-number
Or, run:
controller cpos cpos-number
The interface view is displayed.
Run:
aps mode { one2one bidirection | one-plus-one { bidirection | unidirection } }
A working mode is configured for the APS group. The configuration of an APS working mode takes effect after the shutdown and undo shutdown commands are run on the protect interface. One of the following modes can be configured:
Run:
system-view
The system view is displayed.
Run:
interface interface-type interface-number
Or, run:
controller cpos cpos-number
The protect interface view of the APS group is displayed.
Run:
aps revert wtr-time
The WTR time is set for the APS group.

NOTE:
If one-plus-one unidirection is configured, the switckback delays of both protect interfaces take effect after the working interfaces recover.

If one2one bidirection or one-plus-one bidirection is configured, the switchback delay of the protect interface on the device with the working interface recovering later than the other working interface takes effect on both protect interfaces.