A working mode can be configured for an APS
group. The ME60-X3 /NE40E-X3 supports APS working modes, including automatic APS
switching, and delayed switchback with the wait to restore (WTR) time
configured. An APS working mode must be configured on a protect interface.
Run:
system-view
The system view is displayed.
Run:
interface interface-type interface-number
Or, run:
controller cpos cpos-number
The interface view is displayed.
Run:
aps mode { one2one bidirection | one-plus-one {
bidirection | unidirection } }
A working mode is configured for the APS group.
The configuration of an APS working mode takes effect after the shutdown and
undo shutdown commands are run on the protect interface. One of the following
modes can be configured:
Run:
system-view
The system view is displayed.
Run:
interface interface-type interface-number
Or, run:
controller cpos cpos-number
The protect interface view of the APS group is
displayed.
Run:
aps revert wtr-time
The WTR time is set for the APS group.
NOTE:
If one-plus-one unidirection is configured, the
switckback delays of both protect interfaces take effect after the working
interfaces recover.
If one2one bidirection or one-plus-one bidirection
is configured, the switchback delay of the protect interface on the device with
the working interface recovering later than the other working interface takes
effect on both protect interfaces.