2014年3月12日星期三

Configure the SHDSL service.

The MA5600 supports the SHDSL Internet access service in multiple encapsulation modes, such as IPoA, PPPoA, IPoE, and PPPoE.

Configure the SHDSL line profile.
To configure the SHDSL line profile, run the shdsl line-profile add or shdsl line-profile quickadd command.
huawei(config)#shdsl line-profile quickadd 10 line two-wire rate 2048 2048 psd symmetric transmission Annex-A remote disable probe disable snr-margin ds-curr 10 ds-worst 10 us-curr 10 us-worst 10 bitmap 0x03
Configure the SHDSL alarm profile.
To configure the SHDSL alarm profile, run the shdsl alarm-profile add command.
In this example, the default profile (profile 1) is used.
Configure the SHDSL traffic profile.
To configure the SHDSL traffic profile, run the traffic table command.
In this example, the default profile (profile 1) is used.
Activate the SHDSL port.
huawei(config)#interface shdsl 0/5
huawei(config-if-shdsl-0/5)#deactivate all
huawei(config-if-shdsl-0/5)#alarm-config all 1
huawei(config-if-shdsl-0/5)#activate all profile-index 10
huawei(config-if-shdsl-0/5)#quit
Configure the upstream port.
The SHDSL users of MA5600-2 use the PPPoE authentication. In this case, the smart VLAN is used to identify the users.
huawei(config)#vlan 1300 smart
huawei(config)#port vlan 1300 0/7 0-1
Add the service port.
Ports 0-30 of the SHDSL board in slot 0/5 provide the SHDSL services. To add service ports in batches, run the multi-service-port command.

huawei(config MA5600T )#multi-service-port vlan 1300 port 0/5 0-31 vpi 0 vci 35 rx-cttr 6 tx-cttr 6

2014年3月10日星期一

Configuring the Attributes of an Uplink GPON Port

How to query the statistics for a port, set the working mode of an optical module, and set the alarm thresholds for the receive optical power of the optical module through an uplink Huawei GPON   port.

When dual GPON ports are used for upstream transmission, only 0/0/2 port can be set. After the setting, the parameters of port 0/0/2 are the same as those of port 0/0/1.

To set the password for registering with an OLT through a GPON port, set the lower limit for the receive optical power of an optical module to 5 dBm and the upper limit for the receive optical power to 50 dBm, set the working mode of the optical module of the uplink PON port to auto, run the following command:
huawei(config-if-gponnni-0/0/1)#password
{ passwordvalue<S><Length 1-10> }:huawei

  Command:
          password huawei
huawei(config-if-gponnni-0/0/1)#optical-module threshold rx-power lower-limit 5 upper-limit 50
{ <cr>|bias<K>|temperature<K>|tx-power<K>|voltage<K> }:

  Command:
          optical-module threshold rx-power lower-limit 5 upper-limit 50
huawei(config  MA5600T -if-gponnni-0/0/1)#laser auto

Configuring Local Management (Through a Serial Port)

This topic describes how to connect the maintenance terminal to the MA5620/MA5626 through a local serial port, log in to the MA5620/MA5680T, and then manage the MA5620/MA5626 from the maintenance terminal.

Connect the serial port cable.
Use a standard RS-232 serial port cable to connect the serial port of the PC to the CONSOLE port (maintenance serial port) on the control board of the MA5620/MA5626, as shown in Figure 1.
Start the HyperTerminal.
Set up a connection.
Choose Start > Programs > Accessories > Communications > HyperTerminal on the PC. The Connection Description dialog box is displayed. Enter the connection name, as shown in Figure 3, and click OK.
Figure 3 Setting up a connection
Set the serial port.
On the PC that is connected to the MA5620/MA5626, select the number of the PC terminal serial port. You can select "COM1" or "COM2". In this example, "COM2" is selected, as shown in Figure 4. Click OK.
Figure 4 Selecting the serial port ID
Set the communication parameters of the HyperTerminal.
Set the parameters in the COM2 Properties dialog box, as shown in Figure 5. The parameters are as follows:
Baud rate: 9600 bit/s
Data bit: 8
Parity: None
Stop bit: 1
Flow control: None

NOTE:
The baud rate of the HyperTerminal must be the same as that of the serial port on the MA5620/MA5626. By default, the baud rate of the serial port on the MA5620/MA5626 is 9600 bit/s.
There may be illegible characters in the displayed input information after you log in to the system. This is because the baud rates between the HyperTerminal and the MA5620/MA5626 are not the same. In this case, set a different baud rate to log in to the system. The system supports the baud rates of 9600 bit/s, 19200 bit/s, 38400 bit/s, 57600 bit/s, and 115200 bit/s.

Configuring the Ethernet OAM

How to configure the Ethernet OAM on the MA5612

Create a VLAN.
The VLAN ID is 100, and the VLAN is a smart VLAN.
huawei(config)#vlan 100 smart
Add an upstream port to the VLAN.
Add port 0/7 to VLAN 100.
huawei(config)#port vlan 100 0/7 0
(Optional) Set the native VLAN of the port.
This step is to set the packets of the upstream Ethernet port to or not to carry the VLAN tag. Whether the native VLAN needs to be set for the upstream port depends on whether the upper-layer device connected to the upstream port supports packets carrying a VLAN tag. The setting on the MA5600 must be the same as that on the upper-layer device. In this example, the Ethernet packets are of the untagged type.
huawei(config)#interface scu 0/7
huawei(config-if-scu-0/7)#native-vlan 0 100
huawei(config-if-scu-0/7)#quit
Configure an MD.
MDs with the same index or level cannot be created.
The name format and the name of an MD must be unique.
The total length of the names of an MD and its MAs cannot be longer than 44 characters.
huawei(config)#cfm md 2 name-format string huawei level 3
Configure an MA.
The system supports up to 4096 MAs and each MD can be configured with up to 48 MAs. That is, if an MD is configured with 4096 MAs, the other MDs in the system cannot be configured with any MA. An MA of a non-existing MD cannot be created. An existing MA cannot be created again.
The total length of the names of an MD and its MAs cannot be longer than 44 characters.
huawei(config)#cfm ma 2/6 name-format string huawei-6 vlan 100
Configure an MEP.
MEP refers to the maintenance association end points. Ethernet OAM is used to test the link connectivity by using the MEPs at the two ends of a maintenance channel.
By default, the MEP management function is enabled, the priority of sending CFM packets is 7, and the function of sending CC packets is enabled.
huawei(config)#cfm mep 2/6/0 mepid 260 direction outward port
0/7/0 priority 7
Configure an RMEP.
By default, the detection function of the RMEP is disabled.
huawei(config)#cfm remote-mep-detect enable
(Optional) Set the interval for the MA to transmit CCMs. By default, the interval is one minute.
huawei(config)#cfm ma 2/6 cc-interval 10m
Enable the local CFM globally. By default, the local CFM is disabled globally.
huawei(config)#cfm enable
Enable the detection function of the remote MEP detection globally. By default, the remote MEP detection is disabled globally.
huawei(config)#cfm remote-mep-detect enable
Save the data.
huawei(config)#save

 NOTE:
Configuration on Huawei MA5600 B is the same as that on MA5600_A and it is not repeated here.

2014年3月6日星期四

Configuring Interface Isolation

The S2350 and LS-S2326TP-EI-AC   support isolation at Layer 2 and interworking at Layer 3.

Run:
system-view
The system view is displayed.
(Optional) Run:
port-isolate mode { l2 | all }
Interface isolation is configured.
Run:
interface interface-type interface-number
The Ethernet interface view is displayed.
Run:
am isolate { interface-type interface-number }&<1-8>
Unidirectional isolation is configured on the Ethernet interface.
NOTE:
If interface A is isolated from interface B unidirectionally, packets sent from interface A cannot reach interface B, but packets sent from interface B can reach interface A.
Run:
system-view
The system view is displayed.
(Optional) Run:
port-isolate mode { l2 | all }
Interface isolation is configured.
By default, ports are isolated at Layer 2 but can communicate at Layer 3.
Run:
interface interface-type interface-number
The Ethernet interface view is displayed.
Run:
port-isolate enable [ group group-id ]
Interface isolation is enabled on the Ethernet interface.
By default, interface isolation is disabled.
 NOTE:
Interfaces in an interface isolation group are isolated from each other, but interfaces in different interface isolation groups can communicate. If group-id is not specified, interfaces are added to interface isolation LS-S2326TP-SI-AC   group 1.

2014年3月4日星期二

Configuring the Unicast Negotiation Function for a Client

The unicast negotiation function and parameters for a connection between a client and a clock server are configured on the HUAWEI NE40E-X3  /NE40E-X8   functioning as a 1588 ACR client.

Run:
system-view
The system view is displayed.
Run:
ptp-adaptive enable
1588 ACR is enabled.
Run:
ptp-adaptive device-type client
The 1588 ACR clock working mode is set to client.
(Optional) Run:
ptp-adaptive frequency profile
The 1588 ACR-enabled device to totally comply with ITU-T G.8265.1 is configured.
By default, a 1588 ACR-enabled device complies with ITU-T G.8265.1 partially.
After the ptp-adaptive frequency profile command is run, the default domain value changes to 4. The domain value range changes to 4-23.
(Optional) Run:
ptp-adaptive domain domain-value
A 1588 ACR domain is configured.

NOTE:
The client and clock server, which exchange 1588v2 packets for clock or time synchronization, must be in one 1588 ACR clock domain.

2014年2月25日星期二

Configuring the ISDN PRA Service

This topic is applicable to the scenario where the ISDN users are connected to the Huawei MA5680T   /MA5603T/MA5608T through the ISDN primary rate interface (PRI).

Add the EDTB board.
According to the data plan, add an ISDN PRA service board to slot 0/2.
huawei(config)#board add 0/2 h802EDTB
Add an IUA link set and IUA links.
In the SIGTRAN mode, configure the SIGTRAN protocol stack. Add an IUA link set, and then add IUA links.
huawei(config)#sigtran
huawei(config-sigtran)#iua-linkset add 1 mgid 0 jointly-work enable trafficmode override
iid-map 2 pendingtime cs-mode client
huawei(config-sigtran)#iua-link add 15 1 1401 10.13.4.116 1400 10.14.1.2
jointly-work-with primary-mgc priority 3
 NOTE:
All the ISDN call control messages are sent from the IUA link to the softswitch, whereas the system uses the bearer control messages to communicate with the softswitch through H.248.
Configure the ISDN PRA user data.
huawei(config-sigtran)#quit
huawei(config)#esl user
huawei(config-esl-user)#mgprauser add 0/2/0 0 1 interfaceid 1 terminalid 512

 NOTICE:
Each ISDN PRA user occupies 32 TIDs. You need to input only the first TID when adding an ISDN PRA user.
When the TID profile to which the ISDN PRA user of the MG interface is bound is not a layering profile, the TID must be configured and cannot be within the configured TID range.
When the TID profile to which the ISDN PRA user of the MG interface is bound is a layering profile, the configuration MA5600T    of the TID parameter is not available because the system automatically allocates the TID.